NordVax NOR-5L1366B (48.24 Cu.Ft) Double Door Vaccine/Medical Refrigerator

Built for busy pharmacies handling higher volumes. Consistent 2–8°C performance with spacious, organized storage.

Title

CA

$8,900.00

Qty

Request a Quote

Temperature

2°C – 8°C

Controlled

Capacity

48.24

cubic feet

Shelves

12

Adjustable

Warranty

10 yrs

Compressor · 2 yr parts & labour (no lemon)

Storage Volume 1366 L (48.24 cu ft)
Exterior (W × D × H) 59.1″ × 35.2″ × 75.8″
Net / Gross Weight 227 kg / 271 kg · 500 lb / 598 lb
Shelves 12 adjustable · 35 kg max each
Door Tempered glass double door (auto-heated), self-closing, key-locked
Range 2 °C to 8 °C
Cooling System Forced air, top cooling
Refrigerant R600a hydrocarbon (CFC-free, low GWP)
Voltage 220–240 V / 60 Hz · 20 A outlet required
Rated Current 4.7 A
Ventilation Clearance 4″ rear · 2″ sides minimum
SKU 11-008

Heated glass door

Anti-condensation outer pane kept just above dew point. Contents visible without opening the door — reduces door-open frequency and stabilizes interior temperature.

Calibrated thermometer

Digital display with min/max recall for daily log readings. Calibration certificate included. Supports Health Canada vaccine storage documentation requirements.

High/low temperature alarm

Audible and visual alerts triggered by door-open excursion and temperature deviation. Factory calibrated before shipment.

USB data port

Direct USB extraction of temperature logs for compliance records. No proprietary software required — exports as standard CSV for audit and inspection files.

Adjustable shelving

Five reconfigurable shelves and storage baskets. Adapts to vial trays, insulin pens, and biologics storage formats without additional hardware.

Lockable door

Keyed lock standard. Meets College of Pharmacy requirements for controlled-substance-adjacent storage areas.

Self-closing door

Hinge mechanism returns the door to a sealed position automatically after each use. Prevents temperature drift from accidentally left-open doors during high-traffic dispensing periods.

Top cooling system

Patented forced-air cooling distributed from the top of the cabinet ensures inner temperature uniformity within ±0.5°C across all shelves. Eliminates hot and cold zones common in side-cooled units.

High-efficiency inverter compressor

Variable-speed compressor adjusts cooling output based on real-time demand. Reduces energy consumption by ~35% versus standard fixed-speed compressors and operates at significantly lower noise levels.

Applications

Where to use NOR-5L1366B

Designed for environments where temperature integrity must be continuously maintained and documented for regulatory compliance. Typical deployments include:

Healthcare & Clinical

  • Retail and hospital pharmacies
  • Hospitals and long-term care
  • Medical and walk-in clinics
  • Dental and orthodontic offices
  • Vaccination centres

Research & Specialty

  • Clinical and research laboratories
  • Veterinary clinics and animal hospitals
  • IVF and fertility clinics
  • Biotech manufacturers
  • Public health units

Storage & Logistics

  • Blood banks and plasma centres
  • Cold-chain logistics warehouses
  • Distribution and fulfillment hubs
  • Food and beverage processing
  • Specimen and tissue storage
ALL DEPLOYMENT CONTEXTS SUPPORTED BY HEALTH CANADA & PUBLIC HEALTH COMPLIANT DOCUMENTATION
- Our warranty

Ten years of confidence behind every NordVax.

Every NordVax pharmacy and vaccine refrigerator is backed by a coverage package designed for the realities of cold-chain operation — ten years on the compressor, two full years on parts and labour, and a year-one full unit replacement promise.

10 Years

Compressor Warranty

Compressor part covered against manufacturing defects.

2 Years

Full Parts & Labour

Every part. Every labour hour. Including refrigerant.

1 Year

Replacement Promise

Verified compressor failure or refrigerant leak in year one — new unit, no questions.

- FULL COVERAGE DETAILS

Year-by-year coverage, service area across every Canadian province and territory, what's covered and not covered, and the full claim process.

Certified for regulated cold-chain environments.
UL Listed
Tested and certified by Underwriters Laboratories for North American electrical safety standards.
HEALTH CANADA Meets Health Canada vaccine storage and handling guideline requirements for continuous 2–8 °C monitoring.
PUBLIC HEALTH AGENCY Compatible with Public Health Agency of Canada (PHAC) cold-chain management requirements.
NSF / ANSI 456 Designed to meet the performance requirements of NSF/ANSI 456 vaccine storage standard when paired with a compliant data logger.
REFRIGERANT R600a hydrocarbon — CFC-free, low global warming potential. Compliant with Canadian refrigerant regulations.
PROVINCIAL PHARMACY COLLEGES Configuration supports inspection readiness for provincial pharmacy regulatory authorities across Canada.
NOR-5L1366B Specification Sheet
PDF · SKU 11-008
coming soon...
Installation & Ventilation Guide
PDF · Upright series
coming soon...

-FAQ

NOR-5L1366B — common questions.

Procurement-focused. We respond within 24 hours on business days.

Procurement-focused. We respond within 24 hours on business days.

Still have questions?

Send us your room dimensions and we'll confirm this is the right model before you order.

Request a Quote

Is the NOR-5L1366B the right fit for hospital pharmacy or LTC central fill?

Yes. The NOR-5L1366B at 48.24 cu ft is engineered for high-throughput environments — hospital pharmacy bulk storage, long-term care central fill, vaccine distribution warehouses, and pharmaceutical manufacturer storage. Sized for 200+ door-opens per shift with 12 adjustable shelves for organized vaccine, biologic, and refrigerated compound storage. Built-in 40-hour Li-ion battery backup keeps the unit running through extended outages without an external UPS.

How does the double-door design behave in high-traffic environments?

Both doors are independently operable with heated glass — staff can access one side without disturbing the temperature in the other. Independent self-closing hinges return each door to a sealed position after every use, critical at 200+ door-opens per shift where left-open doors are the leading cause of temperature excursion. Visible stock levels through the heated glass reduce overall door-open frequency.

How is the NOR-5L1366B delivered?

The NOR-5L1366B ships on a pallet with lift-gate service required at delivery. Weight is approximately 500 lb / 598 lb gross. For inside placement past the loading dock or building entrance, GTA white-glove install includes a pallet jack and two-person team. Sites outside the GTA: threshold delivery only — your facility is responsible for moving the unit from the truck to its final location. Confirm loading dock height and door widths before ordering.

How configurable are the shelves on the NOR-5L1366B?

12 adjustable shelves, repositionable in 1-inch increments along full-height side rails. Each shelf holds up to 35 kg, sized to accept standard vial trays, insulin pens, biologics carriers, and pharmacy totes. Mix shelf heights to accommodate different inventory formats without additional hardware. Shelf-card holders are included for label and rotation tracking.

 

Is white-glove install available for the NOR-5L1366B?

Yes for GTA delivery. White-glove for double-door units includes pallet jack delivery from your loading dock to the install location, two-person inside placement, unpacking, and removal of all packaging. We do not include electrical connection — this unit requires a 220–240V / 20A outlet and must be wired by a licensed electrician before delivery. Floor must be level and able to support the unit's gross weight of 500 lb / 598 lb. Contact us with your city, room dimensions, and target install date to confirm scope and schedule.

-Related products

Step up, step down, or add battery backup.

View All

-Pick by use

Where does this model fit your operation?

NOR-5L416 is the standard fit for the vaccine clinic and family practice path. See 

where other models sit relative to your volume and footprint needs.

01 · Front-counter dispensary

Small footprint. Dispensing-station ready.

Sits beside the dispensing workstation — clears most under-counter cabinets at 32″ height

Handles 30–80 door-opens per day

Standard 15A outlet, no dedicated circuit

Typical: independent pharmacy keeping 30–60 days of vaccines and insulin within arm's reach

Title

02 · Vaccine clinic / family practice

Daily-throughput uprights. Heated glass for stock checks.

Heated glass lets staff confirm stock levels without opening the door — critical for temperature stability

Typical: walk-in flu and travel clinic running 80–150 doses per day, restocked weekly from a central depot

Often paired with an NOR-5L42 under-counter as overflow during campaign season

Needs 4″ rear and 2″ side ventilation clearance

Title

03 · Long-term care & central storage

High-capacity uprights and double-door for bulk storage.

Hospital pharmacy or LTC central fill — bulk vaccine, biologics, and refrigerated compounds in one room

Sized for 200+ door-opens per shift

Lockable doors standard; double-door models ship on a pallet with lift-gate service

Consider TempGuard series for sites with unreliable power infrastructure