Free WiFi Temperature Monitor — $290 value, included with every refrigerator

Title

 In Stock — Ships next day

GTA white-glove install available  — learn more

Title

SKU 11-012

Health Canada & Public Health Compliant · TempGuard UPS Built-in

Title

NordVax NOR-5L1006TG · TempGuard Medical Refrigerator with Built-in 10+ Hours UPS — 35.53 cu ft

Medical-grade upright refrigerator with built-in 10+ hours UPS (TempGuard). Maintains a controlled 2–8°C environment through power outages — automatic switchover, no external battery box, single-outlet installation. Heated glass door, audible and visual alarms. Health Canada and Public Health compliant.

Title

CA

$9,000.00

Qty

Request a Quote

Temperature

2– 8°C

Controlled

Capacity

35.53

cubic feet

Backup

10+ hrs

Built-in 
UPS

Warranty

10 yrs

Compressor · 2 yr parts & labour · 2 yr TempGuard unit

Storage Volume 42 L (1.48 cu ft)
Exterior (W × D × H) 17.7" × 18.1" × 22.4"
Net / Gross Weight 23 kg / 25 kg · 51 lb / 55 lb
Shelves 1 shelf + 1 drawer · 12 kg max each
Door Low-E glass, lockable
Range 2 °C to 8 °C
Cooling System Forced air, top cooling
Refrigerant R600a hydrocarbon (CFC-free, low GWP)
Voltage 115 V / 60 Hz · standard 15 A outlet
Rated Power 1.5 A
Ventilation Clearance 4" rear · 2" sides minimum
SKU 11-001
  • Forced Air Cooling: Fast pull-down and uniform temperature control throughout the entire cabinet.
  • Low-E Glass Door: Multi-layered insulated glass prevents exterior condensation and maintains temperature.
  • Integrated Lock: High-security lock keeps sensitive biological samples or inventory safe.
  • Energy Efficient: Uses eco-friendly R600a hydrocarbon refrigerant with zero Ozone Depletion Potential.
  • Biological laboratory sample storage
  • Clinic & pharmacy vaccine storage
  • Industrial chemical storage
  • Academic and research facilities
Parts & Labor 2 Years Limited Warranty
Compressor 5 Years Coverage
Service Type On-Site repair with certified technicians
Electrical Certification cULus Listed (Underwriters Laboratories)
Sanitation Certification NSF/ANSI Standard 7 Compliance
Environmental Standards EPA SNAP Approved hydrocarbon refrigeration system
TempGuard · Built-in UPS

Ten+ hours of refrigeration that doesn't depend on the grid.

The NOR-5L1006TG is North America's first medical-grade vaccine refrigerator with built-in UPS. TempGuard is NordVax's integrated battery backup, designed for clinical sites where a single power event would mean throwing away vaccine stock and re-ordering. The cabinet carries a LiFePO4 battery inside — switching automatically the moment grid power fails, with no external box, no second outlet, and no staff intervention required.

North America's First Medical-Grade Vaccine Refrigerator With Built-In UPS

Plug in. That is the entire installation.

No external UPS box. No second outlet to find. No commissioning, no configuration, no charging delay. The TempGuard battery is integrated inside the cabinet and active from the moment the unit is powered on.

  • 01 Connect to one outlet

    Standard 115V / 15A receptacle. The same outlet powers the refrigerator and the UPS.

  • 02 Power on

    Cabinet begins cooling. UPS is active immediately — no charge-up wait, no commissioning step.

  • 03 That's it

    No external hardware to install, mount, configure, or maintain. One unit, one outlet, one warranty.

T + 0

Grid power fails

No staff notification needed yet. The cabinet keeps cooling without interruption.

T + milliseconds

Automatic switchover

UPS takes over in milliseconds. The compressor never loses power. No temperature excursion.

T + up to 10+ hrs

Continued 2–8°C operation

Display shows battery icon and remaining runtime. On-board audible and visual alarms notify staff that the unit is on battery.

T + grid restored

Auto-recharge

Unit returns to mains automatically. Battery begins recharging in the background while normal operation continues.

Battery technology Lithium iron phosphate (LiFePO4)
Backup runtime Up to 10+ hours — typical clinic load (2–8°C set point, low door-open frequency)
Switchover Automatic, millisecond transition — no manual intervention, no temperature excursion
Power connection Single 115V / 15A outlet — no external battery box, no second receptacle
Recharge behaviour Automatic on power restoration. Background recharge while operating on mains.
Battery monitoring On-board capacity check. Alert raised when battery health drops below the threshold for full backup runtime.
Warranty 2 years on the TempGuard unit — additional to the standard refrigeration warranty (see Warranty tab).
Storage volume 1006 L (35.53 cu ft)
Exterior (W × D × H) 48.0″ × 31.8″ × 75.6″
Net / Gross weight 198 kg / 222 kg · 437 lb / 489 lb
Shelves 5 adjustable, with label-card holders
Door Electric anti-condensation heated glass, self-closing, key-locked
Range 2 °C to 8 °C
Cooling system Forced air, top cooling
Refrigerant R600a hydrocarbon (CFC-free, low GWP)
Voltage 115 V / 60 Hz · standard 15 A outlet
Rated current 2.5 A
Ventilation clearance 4″ rear · 2″ sides minimum
SKU 11-012

Built-in 10+ hours UPS backup

TempGuard battery backup integrated inside the cabinet. Up to 10+ hours of continuous 2–8°C operation during a power outage — covers most utility-grid interruptions and overnight failures without staff intervention.

Automatic switchover

Seamless transition from mains to battery in milliseconds when grid power fails. No manual reset, no temperature excursion, no audible interruption — the cabinet keeps holding 2–8°C while your alert system notifies you of the event.

Single-outlet installation

Plug-and-protect setup — one standard 115V/15A outlet powers both the refrigerator and its built-in UPS. No external battery box, no extra circuit, no second receptacle. Replaces the typical fridge + external UPS combo with a single integrated unit.

Heated glass door

Anti-condensation outer pane kept just above dew point. Contents visible without opening the door — reduces door-open frequency and stabilizes interior temperature.

Calibrated thermometer

Digital display with min/max recall for daily log readings. Calibration certificate included. Supports Health Canada vaccine storage documentation requirements.

High/low temperature alarm

Audible and visual alerts triggered by door-open excursion and temperature deviation. Factory calibrated before shipment.

USB data port

Direct USB extraction of temperature logs for compliance records. No proprietary software required — exports as standard CSV for audit and inspection files.

Adjustable shelving

Five reconfigurable shelves and storage baskets. Adapts to vial trays, insulin pens, and biologics storage formats without additional hardware.

Lockable door

Keyed lock standard. Meets College of Pharmacy requirements for controlled-substance-adjacent storage areas.

Self-closing door

Hinge mechanism returns the door to a sealed position automatically after each use. Prevents temperature drift from accidentally left-open doors during high-traffic dispensing periods.

Top cooling system

Patented forced-air cooling distributed from the top of the cabinet ensures inner temperature uniformity within ±0.5°C across all shelves. Eliminates hot and cold zones common in side-cooled units.

High-efficiency inverter compressor

Variable-speed compressor adjusts cooling output based on real-time demand. Reduces energy consumption by ~35% versus standard fixed-speed compressors and operates at significantly lower noise levels.

Applications

Where to use NOR-5L1006TG

Designed for environments where temperature integrity must be continuously maintained and documented for regulatory compliance. Typical deployments include:

Healthcare & Clinical

  • Retail and hospital pharmacies
  • Hospitals and long-term care
  • Medical and walk-in clinics
  • Dental and orthodontic offices
  • Vaccination centres

Research & Specialty

  • Clinical and research laboratories
  • Veterinary clinics and animal hospitals
  • IVF and fertility clinics
  • Pharmaceutical and biotech manufacturers
  • Public health units

Storage & Logistics

  • Blood banks and plasma centres
  • Cold-chain logistics warehouses
  • Distribution and fulfillment hubs
  • Food and beverage processing
  • Specimen and tissue storage
ALL DEPLOYMENT CONTEXTS SUPPORTED BY HEALTH CANADA & PUBLIC HEALTH COMPLIANT DOCUMENTATION
- Our warranty

Ten years of confidence behind every NordVax.

Every NordVax pharmacy and vaccine refrigerator is backed by a coverage package designed for the realities of cold-chain operation — seven years on the compressor, two full years on parts and labour, and a year-one full unit replacement promise.

2 Years
TempGuard adds

2-Year TempGuard Unit Warranty

The built-in battery backup is covered for two full years — additional to the standard refrigeration warranty below.

10 Years

Compressor Warranty

Compressor part covered against manufacturing defects.

2 Years

Full Parts & Labour

Every part. Every labour hour. Including refrigerant.

1 Year

Replacement Promise

Verified compressor failure or refrigerant leak in year one — new unit, no questions.

- FULL COVERAGE DETAILS

Year-by-year coverage, service area across every Canadian province and territory, what's covered and not covered, and the full claim process.

Certified for regulated cold-chain environments.
UL

UL Listed

Tested and certified by Underwriters Laboratories for North American electrical safety standards.

Health Canada Meets Health Canada vaccine storage and handling guideline requirements for continuous 2–8 °C monitoring.
Public Health Agency Compatible with Public Health Agency of Canada (PHAC) cold-chain management requirements.
NSF / ANSI 456 Designed to meet the performance requirements of NSF/ANSI 456 vaccine storage standard when paired with a compliant data logger.
Refrigerant R600a hydrocarbon — CFC-free, global warming potential. Compliant with Canadian refrigerant regulations.
Provincial pharmacy colleges Configuration supports inspection readiness for provincial pharmacy regulatory authorities across Canada.
NOR-5L1006TG Specification Sheet
PDF · SKU 11-012
coming soon...
Installation & Ventilation Guide
PDF · Upright series
coming soon...

-FAQ

NOR-5L1006TG — common questions.

Procurement-focused. We respond within 

24 hours on business days.

Still have questions?

Send us your room dimensions and power situation — we'll confirm the TG variant is the right fit before you order.

Request a Quote

How long will the built-in UPS keep the refrigerator running during a power outage?

Up to 8 hours of continuous 2–8°C operation, under typical clinic conditions (low door-open frequency, normal ambient temperature). That covers the vast majority of utility grid interruptions, including overnight failures, planned maintenance windows, and most winter storm events. If the outage extends beyond the UPS runtime, the unit will alert you through its audible and visual alarms before battery depletion. For locations with frequent multi-day outages, pair with a generator transfer switch — the TG unit recharges automatically when generator power kicks in.

How does the switchover from mains to battery work? Is there any temperature excursion?

The switchover is automatic and effectively instantaneous (millisecond range) — there is no temperature excursion because the compressor and control electronics never lose power. You do not need to do anything: when grid power fails, the internal UPS takes over; when grid power is restored, the unit switches back to mains and the battery begins recharging. The display and audible alarm indicate the power source change, so you and any connected monitoring system know the unit is running on battery.

What is the difference between NOR-5L1006 and NOR-5L1006TG?

Same cabinet, same capacity (35.53 cu ft), same 10 shelves, same heated glass door, same 2–8°C precision — but the TG variant adds an integrated TempGuard UPS with up to 8 hours of battery backup. The TG version is the right choice if a single power outage would mean throwing away vaccine stock and re-ordering. The non-TG NOR-5L1006 is the right choice if your site has reliable grid power, a building-level generator, or a separate UPS already in place. The TG variant accommodates the battery in a sealed compartment near the compressor.

What ventilation clearance does this unit require?

The NOR-5L1006TG requires a minimum of 4″ rear clearance and 2″ side clearance on both sides. Do not install in an enclosed cabinet or alcove without adequate rear ventilation — insufficient clearance is the leading cause of compressor overload in pharmacy settings. Front clearance should allow the door to open fully — refer to the cabinet width in the Specifications tab and add the door swing arc. The TG variant accommodates the integrated battery module in a sealed compartment near the compressor. If your space is tight, share your room dimensions with us before ordering and we'll confirm fit.

Can a lock be added for controlled-substance-adjacent storage?

The NOR-5L1006TG ships with a lockable door as standard — keyed lock, included. This meets College of Pharmacy guidelines for pharmaceutical storage areas and is sufficient for vaccine and controlled-substance-adjacent refrigerated stock. For Schedule I–IV controlled narcotic storage specifically, a dedicated narcotic safe with a UL-rated time-delay lock is required by provincial pharmacy regulators — the refrigerator alone does not satisfy those requirements. See our Narcotic Safes category for StrongBox and Advance Series options.

What does white-glove delivery include for an upright model this size?

The NOR-5L1006TG ships upright on a pallet. GTA white-glove delivery includes inside placement into your suite or clinic area (not lobby or curbside drop), unpacking, and removal of all packaging materials. We do not include electrical connection — that's coordinated with your electrician or contractor. If you need us to align with your contractor on placement, mounting, or site requirements, we can do that at no extra charge — just let us know at the time of order. Contact us with your city, room dimensions, and target install date to confirm scope and schedule.

-Related products

Step up, step down, or add battery backup.

View All

-Pick by use

Where does this model fit your operation?

NOR-5L42 is the standard fit for the front-counter dispensary. See where 

other models sit relative to your volume and footprint needs.

01 · Front-counter dispensary

Small footprint. Dispensing-station ready.

Sits beside the dispensing workstation — clears most under-counter cabinets at 32″ height

Handles 30–80 door-opens per day

Standard 15A outlet, no dedicated circuit

Typical: independent pharmacy keeping 30–60 days of vaccines and insulin within arm's reach

Title

02 · Vaccine clinic / family practice

Daily-throughput uprights. Heated glass for stock checks.

Heated glass lets staff confirm stock levels without opening the door — critical for temperature stability

Typical: walk-in flu and travel clinic running 80–150 doses per day, restocked weekly from a central depot

Often paired with an NOR-5L42 under-counter as overflow during campaign season

Needs 4″ rear and 2″ side ventilation clearance

Title

03 · Long-term care & central storage

High-capacity uprights and double-door for bulk storage.

Hospital pharmacy or LTC central fill — bulk vaccine, biologics, and refrigerated compounds in one room

Sized for 200+ door-opens per shift

Lockable doors standard; double-door models ship on a pallet with lift-gate service

Consider TempGuard series for sites with unreliable power infrastructure

Title

We don't just ship equipment — we get you running.

All services →

10 Years

Compressor Warranty

Compressor part covered against manufacturing defects.

2 Years

Full Parts & Labour

Every part. Every labour hour. Including refrigerant.

1 Year

Replacement Promise

Verified compressor failure or refrigerant leak in year one — new unit, no questions.